Heat Pump And Dual Cooling Source Deep Dehumidification Fresh Air Unit.
Air Flow Ranges From 1000-20,000 M³/h.
Heat pump type deep dehumidification integrated/split type fresh air unit
Both integral and split structures are available.
Air flow: 1000m³/h to 20,000m³/h
Dual cooling source deep dehumidification fresh air unit
No outdoor unit. The heat pump evaporator and chilled-water coil are used as the cooling source on the treatment side, and the heat pump condensation heat is used as the regenerated rotary heat source to realize double energy-saving.
Air flow: 2000m³/h to 20,000m³/h
Desiccant Rotor Dehumidifiers Highlights
Heat pump type deep dehumidification integrated/split type fresh air unit
- Both integral and split structures are available.
- Double energy savings are achieved by using heat pump evaporative cooling as a source of pre-cooling and post-cooling on the treatment side, and heat pump condensing heat as a source of heat generation for the rotor;
- A state-of-the-art high-fraction polymer deep dehumidification rotor is used, and a heat pump condensing heat is used to create a low-temperature reproduction of the rotor at 50°C.
- Regeneration can be realized through fresh air, room air or mixing air
- The dry bulb temperature of the discharge air on the treatment side is 16 to 21°C, and the humidity content is less than 6 g/kg of dry air;
- The air flow ranges from 1000m³/h to 20,000m³/h, and the selection and customized design can be realized to meet the specific project requirements.
1) Heat pump type deep dehumidification integrated fresh air unit
2) Heat pump type deep dehumidification split type fresh air unit
Dual Cooling source deep dehumidification fresh air unit
- No outdoor unit. The heat pump evaporator and chilled-water coil are used as the cooling source on the treatment side, and the heat pump condensation heat is used as the regenerated rotary heat source to realize double energy-saving.
- A state-of-the-art high-fraction polymer deep dehumidification rotor is used, and heat pump condensing heat is used to create a low-temperature reproduction of the rotor at 50°C.
- Regeneration can be realized through fresh air, room air or mixing air
- Additional modules, such as reheating section, humidifying section, high-efficiency filtration section and other functional sections can be added based on requirements.
- The air flow ranges from 2000m³/h to 20,000m³/h, and the selection and customized design can be realized to meet the specific project requirements.
Project references